Cor-Revicod® 309LT0

General description

Gas shielded flux cored high CrNi alloyed wire for downhand welding

For welding stainless to mild steel and buffer layers in clad steel

Excellent weldability and slag release

High resistance to embrittlement

 

Current type / Shielding gases

DC +

Ar+(˃5-25)% CO2 (EN 439:M21)

100% СО2 (EN439:C1)

15-25 l/min

Approvals

Shielding gases

BV

DNV

GL

LR

М21

309L

309LMS

4332S

SS/CMn

C1

309L

309LMS

 

SS/CMn

Packaging, available sizes and identification

Unit type

Net weight/unit

(kg)

Diameter (mm)

1.2

1.6

Wire reel В202

5

Х

 

Plastic spool S300

12.5

X

X

Classification

AWS A5.22

:E 309LT0-1/-4

ISO 17663

:T 23 12 L R C/M 3

Welding positions

      

Typical chemical composition of all weld metal, (w%)

Shielding gases

C

Mn

Si

Cr

Ni

 

FN

М21/C1

0.03

1.4

0.6

24

12.6

 

15

Mechanical properties of all weld metal

 

Shielding

gas

Condition

Yield strength

(N/mm2)

Tensile strength

(N/mm2)

Elongation

(%)

Impact (ISO), J

+20oС

-20oС 

Required

AWS A5.22

 

 

not required

min 520

min 30

 

 

ISO 17663

 

 

min 320

min 510

min 25

 

  

Typical values after welding

M21/C1 

AW

450

580

36 

 

40