All position gas shielded flux cored wire for high quality welding
Excellent operator appeal due to superior welding characteristics
Full out-of-position capability with higher deposition rates
Exceptional mechanical properties
Superior product consistency with optimal alloy control
Excellent wire feeding
DC +
Ar+(>5-25%) CO2 (EN 439:M21)
15-25 l/min
|
Unit type |
Net weight/unit (kg) |
Diameter (mm) 1.6 |
|
Wire reel B300 |
15 |
Х |
|
AWS A5.20/А5.20М |
:E71T-1M- JH8 |
|
EN 758 |
:T 46 3 P M 1 H10 |

|
Diameter (mm) |
Current (А) |
Welding position |
|||||
|
Voltage |
PA/1G |
PB/2F |
PC/2G |
PF/3Gup |
PG/3Gdown |
PE/4G |
|
|
1.6 |
(А) |
250-350 |
250-350 |
230-280 |
220-260 |
170-240 |
170-240 |
|
(V) |
24-32 |
24-32 |
24-30 |
22-28 |
22-28 |
22-28 |
|
|
Shielding gases |
C |
Mn |
Si |
P |
S |
|
HDM ml/100g |
|
М21 |
0.05 |
1.25 |
0.7 |
0.015 |
0.015 |
|
< 8 |
|
|
Shielding gas |
Condition |
Yield strength (N/mm2) |
Tensile strength (N/mm2) |
Elongation (%) |
Impact (ISO), J |
||
|
-300С |
-400С |
|||||||
|
Required |
AWS A5.20 |
|
|
min.400 |
min.480 |
min. 22 |
|
min. 27 |
|
EN 758 |
|
|
min.460 |
530-680 |
min. 20 |
min.47 |
|
|
|
Typical values after welding |
M21 |
AW |
600 |
650 |
24 |
100 |
75 |
|
| Revicod® 71T-9M |
| Revicod® 70T-1M |
| Revicod® 70T-9С |
| Revicod® 70T-1 |