Cellulosic coated electrode for pipe and general welding
Gives high ductility root welds
Very deep penetration ensures sound pass root
Easy striking, easy slag release
High volume of generated gas eliminates porosity
Reduced problems from dirt and oil on surface.
DC electr.+
Preheating pipe material L360 (X52) required (acc.EN 1011-1)
Pipeclamps to be removed after finishing root pass, start welding the hot pass immediately within 5 min. after root pass
Use electrode directly from metal cans
Use Elex® C6010 for lower hardness in the root pass,when necessary
|
AWS A5.1 |
:E6010 |
|
ISO 2560-A |
:E42 3 C 25 |

|
Steel |
Code |
Type |
|
Pipe material |
EN 10208-1 |
L 210, L 240 |
|
|
EN 10208-2 |
L 240, 290, L 360 |
|
|
EN 10216-1/10217-1 |
P 235, P 275, P 355 |
|
|
API 5LX |
X42, X46, X52 |
|
|
Gaz de France |
X42, X46, X52 |
|
С |
Mn |
Si |
|
0.09 |
0.5 |
0.4 |
|
|
Condition |
Yield strength, (N/mm2) |
Tensile strength (N/mm2) |
Elongation (%) |
Impact (ISO), J |
|||
|
-20оС |
-29оС |
-30oC |
||||||
|
Required |
AWS A5.1 |
|
min.331 |
min.414 |
min.22 |
|
27 |
|
|
ISO 2560-A |
|
min.420 |
500-640 |
min.20 |
|
|
47 |
|
|
Typical values after welding |
AW |
440 |
520 |
26 |
70 |
|
65 |
|