Revishield® 71T8-Ni1

General description

Self shielded: easiest equipment arrangement

All position welding

Easy to weld in vertical up position

All passes

Good impact and CTOD toughness

Current type / Shielding gases

DC -

 

Approvals

ABS

BV

DNV

FORCE

GL

LR

RINA

TÜV

3SA, 3YSA

SA3YMHH

IIIYMSH10

+

3YSH10

3S, 3YSH15

3S, 3YS

+

Welding positions

                     

Classification

AWS A5.29/A5.29M

:E71Т8-Ni1

Suggestions for use

For mild and higher strength steel, not exceeding the yield strength range of the electrode weld deposit

General plate fabrication, including bridge construction, hull plate and stiffener welding on ships and barges, off shore

For semi- and full automatic welding

Typical chemical composition of all weld metal, (w%)

C

Mn

Si

P

S

Al

Ni

0.8

1.1

0.27

0.008

0.003

0.85

0.9

Mechanical properties of all weld metal

 

Shielding

gas

Condition

Yield strength (N/mm2)

Tensile strength (N/mm2)

Elongation (%)

Impact (ISO), J

+20oС

-29oС

Required

AWS A5.29

 

 

min 400

480-620

20

 

27

Typical values after welding

 

AW

465

540

26

 

115